 |  | (118)
- Converts raw-edged holes to smooth, neat, insulated holes.
- Locking fingers "snap" into holes with fingertip pressure.
- Withstands a push back force of 35 pounds.
- Insulates and mechanically protects electrical and telecommunications cables, tubing, hose, rope, and utility lines.
- Available in 58 sizes for use in 1/4" (6.4 mm) to 6" (152.4 mm) diameter holes.
Locking fingers in fractional increment up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (5)
- Absorbs vibration, cushions and insulates cables, tubing, hoses or shafts with limited internal clearance.
- Molded of 6/6 "Nylon".
- Fingertip pressure snap-locks the bushing into its mounting hole.
- Flexible "shutters" adjust to accommodate and support any shape from .125" (3.2 mm) to a maximum diameter of .750" (19.0 mm).
|
 |
 |
 |
 |
 |  | (9)
- Flexible "shutters" adjust to accommodate and support any shape from .125" (3.2 mm) to a maximum diameter of 1.062" (26.9 mm).
- Absorbs vibration, cushions and insulates cables, tubing, hoses or shafts with limited internal clearance.
- Fingertip pressure snap-locks the bushing into its mounting hole.
Locking fingers in fractional increments up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (8)
- Converts raw-edged holes to smooth, neat, insulated holes.
- Flexible "shutters" to absorb vibration on the inside diameter.
- Locking fingers "snap" into holes with fingertip pressure.
- Withstands a push back force of 35 pounds.
- Insulates and mechanically protects electrical and telecommunications cables, tubing, hose, rope, and utility lines.
- Available in 8 sizes for use in 1/2" (12.7 mm) to 1 1/2" (38.1 mm) diameter holes.
Locking fingers in fractional increments up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (9)
- Split design allows side entry and encirclement of preassembled harnesses, capillary tubes or other assemblies that have segments larger than the bushing’s ID.
- Parts can be assembled into holes that already contain cables or tubing.
- Only fingertip pressure required to snap-lock the bushing into its mounting hole.
- Flexible "shutters" adjust to accommodate and support any shape from .125" to a maximum diameter of 1.062".
- Absorbs vibration, cushions and insulates cables, tubing, hoses or shafts with limited internal clearance.
- Available in 9 sizes for use in 1/2" (12.7 mm) to 1 1/2" (38.1 mm) diameter holes.
Locking fingers in fractional increments up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (24)
- Twelve sizes for use in mounting holes from 3/8" (9.5 mm) to 1 1/2" (38.1 mm).
- Split design allows side entry and encirclement of preassembled harnesses, capillary tubes or other assemblies that have segments larger than the bushing’s ID.
- May also be assembled into holes that already contain cable, wire or other filaments.
- Fingertip pressure snap-locks the bushing into its mounting hole.
Locking fingers in fractional increments up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (20)
- Converts raw-edged holes to smooth, neat, insulated holes.
- Locking fingers "snap" into holes with fingertip pressure.
- Withstands a push back force of 35 pounds.
- Insulates and mechanically protects electrical and telecommunications cables, tubing, hose, rope, and utility lines.
- Available in 10 sizes for use in 1/2" (12.7 mm) to 2" (50.8 mm) diameter holes.
Locking fingers in fractional increments up to the maximum panel thickness.
|
 |
 |
 |
 |
 |  | (34)
- Available in seventeen sizes for use in mounting holes from 3/16" (4.7 mm) to 1" (25.4 mm).
- Insulating feed-thru bushings for limited internal clearance (minimum .125" or 3.2 mm) applications.
- Insulates and isolates electric or telecommunications cables as well as low RPM shafts and push pull rods.
- Locking fingers hold securely after only fingertip pressure “snap-in” installation.
Locking fingers in fractional increments up to the maximum panel thickness.
Search 34 Items |
 |
 |
 |
 |
 |  | (8)
- Convert raw-edged holes to smooth ones.
- Locking fingers “snap” into holes with fingertip pressure.
- Withstands a push back force of 35 pounds.
- Four sizes for use in .630" (16.0 mm) to 1.260" (32.0 mm) diameter holes.
- Locks firmly into panel up to .098" (2.5 mm) thick.
|
 |
 |
 |
 |
 |  | (3)
- Provides insulation plus light strain relief.
- Suitable for 1/8" (3.2 mm) to 1/4"(6.4 mm) diameter cable, tubing or hose.
- The ID opens to accept the cable then closes firmly when installed into the mounting hole.
|
 |
 |
 |
 |
 |  | (3)
- Converts raw-edge pipe ends with NPT threads to smooth insulated ends.
- Insulates and mechanically protects lamp cords, other electrical and communications cables, tubing, hose, rope, and utility lines.
- 1/4" and 3/8" NPT sizes molded of phenolic material.
- 1/8" NPT size molded of type 6/6 “Nylon”.
- Quick Specs below do not apply.
|
 |
 |
 |
 |
 |  | (6)
- Extra internal insulating sleeve covers the entire inside diameter, “blinding” the ID to openings around the locking fingers.
- Large radius exit hole.
|
 |
 |
 |
 |
 |  | (4)
- Use with Flexible Armored Cable (BX) and Flexible Metallic Conduit (FMC), to insulate rough cut conduit ends.
- Suitable for installation at temperatures up to 90°C and as low as -40°C.
- Chamfered lead-in allows for fast installation.
- Size-marked for easy identification.
- Molded of high dielectric polyethylene.
|
 |
 |
 |
 |
 |  | A convenient assortment of various bushings for prototype and laboratory use. Lid Card indicates mounting hole sizes and bushing IDs.
|